Cold Room Compressor Health and Door Monitor for Small Cold Stores

A final year project that builds a retrofit monitor for walk-in cold rooms in small cold stores, restaurants, dairies and fruit sellers: temperature, door state and compressor current, with anomaly detection that spots a failing compressor or icing coil days before the room warms up. The aim is fewer spoiled loads and planned repairs instead of emergency ones.

Difficulty

Advanced

Needs a team, real planning, and a supervisor who knows the area.
Effort

2 semesters · 3 students

Deliverables

7 to ship

3 optional extras

Suggested stack

ESP32Current transformers (SCT-013)DS18B20 probes and reed switchMQTTPython (pandas, scikit-learn)PostgreSQL or TimescaleDBReact dashboard
A suggestion, not a requirement. Swap anything for what you already know.

What you should ship

  • A retrofit node that measures room air temperature, evaporator coil temperature, door open state and compressor current without modifying the refrigeration circuit.
  • Cycle extraction from compressor current: start time, run length, off time, starting current and running current for every compressor cycle.
  • Door discipline reporting: open events, total open minutes per shift and alarms when a door is left open.
  • An anomaly model per cold room trained on its own normal behaviour that flags rising run fraction, short cycling, abnormal starting current and slow pull-down after defrost.
  • Plain-language alerts to the owner and technician, such as compressor running much longer than normal for this outdoor temperature, with the supporting chart attached.
  • A dashboard with temperature compliance, compressor duty cycle, energy estimate and an event timeline for each room.
  • An evaluation using at least four weeks of real data plus deliberately induced faults on a test fridge or small cold room, such as a blocked condenser or door left ajar.

If you have time left

  • Estimate the energy wasted by door openings and poor defrost timing and show it in money.
  • Give technicians a shared log where they record the fix, and use it to label future anomalies.
  • Support several rooms per site on one gateway with LoRa for large cold stores.

The problem small cold stores have with compressors

Walk-in cold rooms hold potatoes and fruit in cold stores, milk and yoghurt in dairies, meat and vegetables in restaurants, and medicines in pharmacy warehouses. Owners usually learn something is wrong when the room is already warm: a compressor has failed, a coil has iced over, or a door was left open overnight. By then the stock may be lost and the repair is an emergency call-out at the worst time. Refrigeration technicians say failing compressors give warnings (longer run times, short cycling, higher starting current) days before they stop, but nobody is watching those signals in a small business.

What already exists and the gap

  • Monnit sells wireless temperature, door and current sensors for commercial refrigeration with alerts for rising temperature, open doors and abnormal motor activity.
  • Swift Sensors offers continuous refrigeration monitoring for walk-ins, freezers and cold storage rooms, with alerts for failing compressors and open doors.
  • SensorPush is a low-cost temperature and humidity logger that many businesses place in fridges and walk-in coolers, with no equipment health signals.

These products are strong on temperature alarms. The gap is a low-cost retrofit that learns each room's own normal compressor behaviour, explains anomalies in terms a technician understands, and is priced for a small cold store or dairy in markets where these products are imported at high cost. Unlike a transport logger for vaccines, this is about the machine that makes the cold, not just the temperature of the goods.

What you build

  • Room node: an ESP32 with temperature probes for room air and coil, a reed switch on the door, and a split-core current transformer on the compressor supply.
  • Edge processing: cycle extraction on the device so only cycle summaries and events are sent.
  • Backend: MQTT ingestion, storage, an anomaly service and alerting.
  • Dashboard: per-room compliance, duty cycle, door events and anomaly explanations.

Users: the owner, who wants alerts and reports, and the technician, who wants cycle charts to diagnose faults.

The technically interesting part

Compressor behaviour depends on outdoor temperature, how much stock was loaded, door openings and defrost cycles, so a fixed threshold on run time produces constant false alarms in summer. The hard part is building a per-room baseline that accounts for these factors, for example a regression of run fraction on outdoor temperature and door-open minutes, and then flagging residuals that persist. Short cycling and starting current need their own detectors. Because real failures are rare during a project, you must induce faults safely on a test unit (partly block the condenser airflow, let the coil ice) to show that your detectors fire. Evaluators will want to see detection time, false alarm rate and explanations, not only a model score.

How to evaluate it

  • Cycle extraction accuracy against a manually labelled current trace.
  • Induced faults: for each fault type, time from fault start to alert, over repeated trials.
  • False alarms per room per week on normal operation, including hot days and heavy loading days.
  • Temperature measurement accuracy against a calibrated reference probe.
  • A review session with a refrigeration technician rating whether each alert and its explanation made sense.

Suggested plan

  1. Month 1: visit two cold rooms, talk to a technician, install a simple logger to start collecting data early.
  2. Month 2: node hardware, cycle extraction on the device.
  3. Month 3: backend, storage, dashboard basics and door reporting.
  4. Month 4: baseline models and anomaly detectors on collected data.
  5. Month 5: test fridge fault experiments.
  6. Month 6 to 7: field evaluation, technician review and report.

Path to a product

The first customer is a dairy, restaurant group or potato cold store owner who has lost a load. Sell the node with installation and a monthly monitoring fee per room. Refrigeration service companies are the best channel: they can offer monitoring with their maintenance contracts and turn emergency calls into planned visits. Pharmacy distributors with cold rooms are a later market with stricter compliance needs.

Scope warning

Do not open or modify the refrigerant circuit; everything is clip-on or taped on. Do not build a full refrigeration controller that switches the compressor. Do not claim to predict failures you have never observed; say which faults you tested and how.

Learn what you need on Sefism

Get help with this idea

Getting real data early is the most important step, so start logging in the first month. If you want a second opinion on scope, hardware choices or how to set up the evaluation before you commit, bring your plan and your bill of materials and we will pressure-test it together. New here? Create a free account first.

Ideas and guidance, not finished projects

These are project ideas and scoping guidance, published free for students to use as a starting point. I do not build, write, or sell final-year projects, and I do not complete coursework for anyone. Take an idea, make it yours, and build it.

Not sure this one fits you?

I help students pick an idea that matches their skills and their deadline, then scope it down until it is finishable. Guidance only, never done for you.

Discuss this idea
Work with me

Stuck on something specific?

Writing only gets you so far. If you want an answer to your situation rather than the general case, book a session and we will work through it together. Sessions are free for approved Sefism members, and a few slots open each week.